ENGINEERING SPECIFICATION · TS EN 13031-1 · DIN

vtsproje® Ventilation & Circulation Systems; horizontal air flow (HAF) fans mix the greenhouse air so temperature and humidity are uniform everywhere, while exhaust fans remove humid air. Eliminating stagnant zones and condensation on leaves reduces the risk of fungal disease.

Figure 1: Circulation fan inside the greenhouse
Figure 1: Circulation fan inside the greenhouse
Figure 2: HAF fan hung below the roof
Figure 2: HAF fan hung below the roof
Figure 3: Fans installed in rows
Figure 3: Fans installed in rows
Figure 4: Exhaust fan application
Figure 4: Exhaust fan application

1. Horizontal Air Flow (HAF)

Circulation fans are installed in rows along the greenhouse in two opposite lines, creating a closed air loop. The effect of heating, CO2 enrichment and fogging is spread evenly over the whole area.

System Components:

  • Circulation (HAF) Fan: ≈ 5,000 – 10,000 m³/h airflow, low energy motor
  • Fan Spacing: Every 25 – 35 m along the line, in the airflow direction
  • Exhaust Fans: Shuttered fans on the gable wall for moisture removal and ventilation
  • Control: Operation by humidity and temperature via climate computer

2. Benefits

A uniform climate evens out crop growth along the greenhouse, improving quality and yield. Preventing water films on leaves reduces pressure from diseases such as Botrytis and lowers the need for spraying.

3. Technical Specification Table

Technical Parameter Value / Scope Standard / Reference
Fan Airflow ≈ 5,000 – 10,000 m³/h ISO 5801
Motor Power ≈ 0.15 – 0.55 kW Manufacturer data
Protection Class IP55 EN 60529
Layout 25 – 35 m spacing, two-way line Project calculation
Control Climate computer / thermostat – hygrostat –
Suspension Loads Included in structural calculation EN 13031-1

Get a Quote for Your Ventilation Project

Contact our engineers for a calculation and turnkey installation quote tailored to your greenhouse area, climate zone and crop targets.