vtsproje® Hot Water Heating Systems; water heated in the boiler circulates through steel pipes laid along the greenhouse, delivering heat evenly and silently at crop level. Pipe rails also serve as tracks for harvest and maintenance trolleys.
1. System Architecture
Hot water produced in the boiler house is distributed to the heating circuits by 3-way mixing valves and circulation pumps. Pipe rails between rows heat from floor level, while optional grow pipes add heat at stem level.
Heating Circuits:
- Pipe Rail: Ø 51 mm galvanised steel pipe at floor level between rows; also used as trolley track
- Grow Pipe: Ø 28 – 35 mm, movable line at stem level
- Perimeter / Gutter Line: Reduces condensation and snow accumulation along side walls and gutters
- Manifold: Flow and return manifolds, balancing valves and air vents
2. Efficiency and Control
Heat enters the greenhouse over a large surface with a small temperature difference, reducing crop stress. The climate computer continuously adjusts water temperature through the mixing valve according to outside air, radiation and inside temperature. A heat storage tank can shift daytime heat to the night.
3. Technical Specification Table
| Technical Parameter | Value / Scope | Standard / Reference |
|---|---|---|
| Water Temperature | 40 – 90 °C (per circuit) | Project calculation |
| Pipe Rail Diameter | Ø 51 mm, hot-dip galvanised | EN 10255 / EN 10217 |
| Grow Pipe Diameter | Ø 28 – 35 mm | EN 10217 |
| Boiler | Natural gas, coal, biomass, heat pump | EN 303 |
| Mixing and Control | Motorised 3-way valve + climate computer | – |
| Suspension and Loads | Included in structural calculation | EN 13031-1 |
Get a Quote for Your Hot Water Heating Project
Contact our engineers for a calculation and turnkey installation quote tailored to your greenhouse area, climate zone and crop targets.