ENGINEERING SPECIFICATION · TS EN 13031-1 · DIN

vtsproje® Warm Air Heating Systems; air heated in the generator is distributed evenly along the greenhouse by fans and polyethylene ducts. The system starts quickly and needs a lower initial investment than hot water heating, making it ideal for frost protection and shoulder-season support heating.

Figure 1: Warm air heater installed inside the greenhouse
Figure 1: Warm air heater installed inside the greenhouse
Figure 2: Air heater connected to the distribution duct
Figure 2: Air heater connected to the distribution duct
Figure 3: Warm air distribution along the greenhouse
Figure 3: Warm air distribution along the greenhouse
Figure 4: Air heater and burner unit
Figure 4: Air heater and burner unit

1. Operating Principle and Components

Heat produced by the burner is transferred to the greenhouse air through an indirect-fired heat exchanger; flue gases are discharged outside and never reach the crop. An axial fan blows the warm air into perforated polyethylene ducts that distribute it evenly close to crop level.

System Components:

  • Air Heater: Natural gas, LPG, diesel or biomass fired unit with indirect heat exchanger
  • Distribution Duct: Perforated PE duct, Ø 400 – 800 mm, hole spacing calculated for greenhouse length
  • Suspension: Units and ducts are hung from the structure according to EN 13031-1 load assumptions
  • Control: Stepped or modulating operation via thermostat or climate computer

2. Capacity Calculation and Layout

Heating capacity is calculated from the cladding surface area, the heat transfer coefficient (U value) of the cladding and the design temperature difference between inside and outside. The number and position of units are designed so that air circulates without interruption along the greenhouse.

  • Fast Response: Starts within minutes on cold nights
  • Low Investment: No boiler house or pipe network needed
  • Flexible Use: Can back up or supplement hot water heating systems

3. Technical Specification Table

Technical Parameter Value / Scope Standard / Reference
Unit Heating Capacity 100 – 350 kW (per project) Heat loss calculation
Firing Type Indirect, with heat exchanger, flue gas outside EN 1020 (gas) / EN 13842 (oil)
Fuel Natural gas, LPG, diesel, biomass Manufacturer certificate
Air Distribution Perforated PE duct Ø 400 – 800 mm Calculated for greenhouse length
Suspension Load Included in structural calculation EN 13031-1
Control Thermostat / climate computer –